... inlet opening , is all that is required in some instances , as in badly placed closets . For large rooms , the sunlight ventilators are found to answer admirably . They should be provided with a glass shade , placed below them to ...
... inlet opening , is all that is required in some instances , as in badly placed closets . For large rooms , the sunlight ventilators are found to answer admirably . They should be provided with a glass shade , placed below them to ...
Seite 57
... inlet apertures , which are placed ver- tically like Tobin's tubes , etc. It is im- portant in all these contrivances , where the outer air passes through a chamber in which the back of the grate and the flue is placed , that the back ...
... inlet apertures , which are placed ver- tically like Tobin's tubes , etc. It is im- portant in all these contrivances , where the outer air passes through a chamber in which the back of the grate and the flue is placed , that the back ...
Seite 61
... inlet opening , and so made to pro- pel air into the apartment through an aperture in the wall placed higher than people's heads , and made in a slanting direction , so that the entering air is shot upwards towards the center of the ...
... inlet opening , and so made to pro- pel air into the apartment through an aperture in the wall placed higher than people's heads , and made in a slanting direction , so that the entering air is shot upwards towards the center of the ...
Seite 120
... inlet , and a consider- able fall in the trap itself . In many instances , with sewers already laid , sufficient fall cannot be got to introduce these traps . Weaver's trap is really a siphon , as already mentioned , with an upright air ...
... inlet , and a consider- able fall in the trap itself . In many instances , with sewers already laid , sufficient fall cannot be got to introduce these traps . Weaver's trap is really a siphon , as already mentioned , with an upright air ...
Seite 122
... inlet at the lower end of the sewer , pass along it through its whole length , and escape by the ventilating pipe or pipes just mentioned , and no foul air can accumulate in any part of the sewer . If any foul air escapes at the air inlets ...
... inlet at the lower end of the sewer , pass along it through its whole length , and escape by the ventilating pipe or pipes just mentioned , and no foul air can accumulate in any part of the sewer . If any foul air escapes at the air inlets ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
allowed aperture ball valve basement basin Bostel bricks carbonic acid carried ceiling cesspools cistern cloth compartment containing contrivance course covered cowl cylinder D-trap discharge disconnected drains draught drinking water dust edition Engineer escape especially excretal matters exit shaft filtering material fixed floor flue foul air foul water frequently galvanized iron ground hard waters holes hopper closet house sewer Illustrated impervious impure inches inside instances iron grating joints kind louvres lower sash means ments Messrs metal milk of lime necessary NOSTRAND'S PUBLICATIONS nuisance organic matter outer air overflow pipe pass pervious placed plate purposes quantity of water rain-water receptacles refuse matters sanitary side sinks siphon trap soft water soil pipe sometimes stoneware stoves stratum supply of water surface tank thrown tion TREATISE tube typhoid fever valve box valve closet ventilating pipe vertical wall warm waste pipes water closets water pipes water-waste preventer window
Beliebte Passagen
Seite 79 - It ought to be an absolute condition for a public water supply that it should be uncontaminated by drainage.
Seite 53 - ... does, whereas one gas burner will consume as much oxygen and give out as much carbonic acid as five or six men, or even more. This is why it is commonly considered that gas is more injurious than lamps or candles...