Medical Radiography and Photography, Bände 33-34Eastman Kodak Company, 1957 |
Im Buch
Ergebnisse 1-3 von 13
Seite 1
... lens would ap- proach 1000 times the radius of curvature . The x - ray beam , especially if soft rays were used , would be partially or totally absorbed in passing through the lens ; also , the weakened beam would suffer further ...
... lens would ap- proach 1000 times the radius of curvature . The x - ray beam , especially if soft rays were used , would be partially or totally absorbed in passing through the lens ; also , the weakened beam would suffer further ...
Seite 53
... lens -even when supplemented with close - up lenses- the full - area , extra - fine - grain ground glass shows the ... lens . The front lens component ( 3 elements ) can be inter- changed with 6 - element components for telephoto and ...
... lens -even when supplemented with close - up lenses- the full - area , extra - fine - grain ground glass shows the ... lens . The front lens component ( 3 elements ) can be inter- changed with 6 - element components for telephoto and ...
Seite 83
... lens and shutter have been remounted on an im- provised extension tube that places the lens 11⁄2 inches further from the film than is usual . A sup- plementary lens , a Kodak Telek Lens 1- , makes possible a fixed working distance of 2 ...
... lens and shutter have been remounted on an im- provised extension tube that places the lens 11⁄2 inches further from the film than is usual . A sup- plementary lens , a Kodak Telek Lens 1- , makes possible a fixed working distance of 2 ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
Anteroposterior radiograph Artery baby barium barium enema basal body-section radiograph bone bronchi Bronchopulmonary Segments calcification camera cavity cent central ray Cerebral chest clinical Coccidioidomycosis colon color color temperature contrast medium demonstrated Department of Radiology diagnosis duct Eastman Kodak Company Ektachrome Film employed emulsion esophagus examination exposure filter fluoroscopic graphs Hospital illustrated inches infant injected Internal Carotid kilovoltage Kodak Medical LATERAL PROJECTION lateral radiographs lens lesion lobe lung macrosection Medical Division Medical Radiography Medical X-ray Film Megavoltage Microradiography microscope minutes at 68 normal oblique parotid gland patient supine photographic Photomicrograph Pneumoencephalogram polyps position posterior Posteroanterior radiograph radiation radio radiograph Radiography and Photography radiologist Radiology Rochester Roentgen roentgenograms Roentgenol Royal Blue scapula screen segment showing Sialography skull slides Spermatozoa spot-compression stain stomach studies submandibular submandibular gland target-film distance technical factors tion tumor upper Ventricle vertebrae visualized X-ray Technicians x-ray tube York