... TEMPERATURE CONTROL † C. F. BRIDGMAN * THE METHOD for controlling the temperature of the processing solution must be adequate or all the advantages of even an expensive x - ray proc- essing tank will be nullified . The equipment must be ...
... TEMPERATURE CONTROL † C. F. BRIDGMAN * THE METHOD for controlling the temperature of the processing solution must be adequate or all the advantages of even an expensive x - ray proc- essing tank will be nullified . The equipment must be ...
Seite 72
... Temperature - Control Systems All of the systems available for controlling the temperature of processing solutions may be classified in one of two general groups - pro- portional or on - off . Proportional control utilizes a constant ...
... Temperature - Control Systems All of the systems available for controlling the temperature of processing solutions may be classified in one of two general groups - pro- portional or on - off . Proportional control utilizes a constant ...
Seite 87
... temperature rises considerably , the rap- id return of the water - jacket temperature to the desired processing range may be secured with this type of valve . This is done by allowing sufficient cold water to flow through the valve ...
... temperature rises considerably , the rap- id return of the water - jacket temperature to the desired processing range may be secured with this type of valve . This is done by allowing sufficient cold water to flow through the valve ...
Inhalt
NTENTS Brief BiographiesCaldwell Cover | 2 |
LUME | 25 |
The publisher accepts no responsibility for opinions expressed by contributors | 33 |
4 weitere Abschnitte werden nicht angezeigt.
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
abdomen angle Blue Brand bone bronchi camera cassette cavity centimeters chemical chest clinical color cover darkroom dermoid cyst developer solution diagnosis diaphragm distal distance DRYER Eastman Kodak Company electric Electrocardiograph employed equipment examination exposure feet Figure 11 fixer solution focal length glass Hospital illumination illustrations inches infrared infrared photography injected insert tanks intensifying screens iodized oil Kodachrome Kodak Electrocardiograph Kodak Liquid X-ray Kodak X-ray laboratory lacrimal lacrimal sac lamp larynx lens lenses lesions light lightlock lighttight loading bench located lodestone lung magnification material medical photographer Medical Radiography ment nasolacrimal duct navicular bone normal ovary paper patient posteroanterior Processing Hanger processing room processing solutions processing tanks Published RADIOGRAPHIC ROOM radiographs radiologist Radiology records Replenisher rinsing Rochester safelight shown in Figure SINK slides space specimen surface technic temperature thermoregulator tion tissue tube tumor utilized valve visualized wall water jacket X-ray Film X-ray Processing York