Medical Radiography and Photography, Bände 24-25Eastman Kodak Company, 1948 |
Im Buch
Ergebnisse 1-3 von 4
Seite 66
... lacrimal ducts . This examina- tion may prove helpful in cases of dacrocystitis ; dacryoliths or mucocele ; irregularity or thicken- ing of the lining of the ducts ; stenosis ; congenital or acquired nasolacrimal defects . If variations ...
... lacrimal ducts . This examina- tion may prove helpful in cases of dacrocystitis ; dacryoliths or mucocele ; irregularity or thicken- ing of the lining of the ducts ; stenosis ; congenital or acquired nasolacrimal defects . If variations ...
Seite 67
... lacrimal lake . until reaching the lacrimal sac . This structure is situated in the lacrimal fossa , a deep groove formed by the lacrimal bone and the frontal process of the maxillary bone . The oval sac is about 12 millimeters long ...
... lacrimal lake . until reaching the lacrimal sac . This structure is situated in the lacrimal fossa , a deep groove formed by the lacrimal bone and the frontal process of the maxillary bone . The oval sac is about 12 millimeters long ...
Seite 68
... lacrimal system is well demonstrated by the ac- companying illustrations . In Figure 3 ( page 67 ) , oil has been injected into the upper and lower FIGURE 6 - Posteroanterior radiograph showing passage of iodized oil from lacrimal sac ...
... lacrimal system is well demonstrated by the ac- companying illustrations . In Figure 3 ( page 67 ) , oil has been injected into the upper and lower FIGURE 6 - Posteroanterior radiograph showing passage of iodized oil from lacrimal sac ...
Inhalt
NTENTS Brief BiographiesCaldwell Cover | 2 |
LUME | 25 |
The publisher accepts no responsibility for opinions expressed by contributors | 33 |
4 weitere Abschnitte werden nicht angezeigt.
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
abdomen angle Blue Brand bone bronchi camera cassette cavity centimeters chemical chest clinical color cover darkroom dermoid cyst developer solution diagnosis diaphragm distal distance DRYER Eastman Kodak Company electric Electrocardiograph employed equipment examination exposure feet Figure 11 fixer solution focal length glass Hospital illumination illustrations inches infrared infrared photography injected insert tanks intensifying screens iodized oil Kodachrome Kodak Electrocardiograph Kodak Liquid X-ray Kodak X-ray laboratory lacrimal lacrimal sac lamp larynx lens lenses lesions light lightlock lighttight loading bench located lodestone lung magnification material medical photographer Medical Radiography ment nasolacrimal duct navicular bone normal ovary paper patient posteroanterior Processing Hanger processing room processing solutions processing tanks Published RADIOGRAPHIC ROOM radiographs radiologist Radiology records Replenisher rinsing Rochester safelight shown in Figure SINK slides space specimen surface technic temperature thermoregulator tion tissue tube tumor utilized valve visualized wall water jacket X-ray Film X-ray Processing York