... x - ray absorption used for the cover . The register board is desirable , although not necessary , for the other two technics that employ much higher kilovoltages . For the latter , a standard x - ray cassette may be employed if there ...
... x - ray absorption used for the cover . The register board is desirable , although not necessary , for the other two technics that employ much higher kilovoltages . For the latter , a standard x - ray cassette may be employed if there ...
Seite 77
... x - ray tube specifically designed for use with a low - voltage x - ray machine should be utilized . Six kilovolts have been found to be most satisfactory . Kilovoltages as high as 10 or 15 also will produce acceptable re- sults ...
... x - ray tube specifically designed for use with a low - voltage x - ray machine should be utilized . Six kilovolts have been found to be most satisfactory . Kilovoltages as high as 10 or 15 also will produce acceptable re- sults ...
Seite 78
LEAD FOIL STAMP ( DESIGN UP ) FILM HEAVILY FILTERED X - RAYS , 160-250 KV FIGURE 5 - Arrangement of materials for use in x - ray electronography . emission sufficient to penetrate the stamp ( Figure 5 ) . The lead intensifying screens ...
LEAD FOIL STAMP ( DESIGN UP ) FILM HEAVILY FILTERED X - RAYS , 160-250 KV FIGURE 5 - Arrangement of materials for use in x - ray electronography . emission sufficient to penetrate the stamp ( Figure 5 ) . The lead intensifying screens ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
abdomen acridine orange amitosis anteroposterior articulations bile duct biliar blood body-section radiography cálculos camera casos cells células central ray cholangiography ción citoplasma colangiografía colédoco color common bile duct common duct conducto hepático contrast material costal cranial cytoplasm debe demonstrated después diagnosis diámetro diaphragm distancia Eastman Kodak Company enfermo examination exposure Figure film filter fluorochromes foramina frontal bone gallbladder gland glándula graph hemithorax hepatic Hospital illustrations imagen injection Lateral radiograph lesions luego Medical Medical Radiography mente method método microscope neoplásicas normal nuclear núcleo nucléolos oblique Oblique Projection pág parietal parietal foramina patient photographic Photomicrography plane portal vein portion posición posterior posteroanterior procedure projection pueden radiation radio radiografía radiográfica radiograph radiologists Radiology radiolucent radiopaque ribs showing skull slide specimen splenic splenic vein stained stamp Stereoscopic substancia de contraste superior mesenteric vein surface technic thoracic vertebrae tion tissue transverse tube tumor Type vertebral vesícula vía visualized x-ray York