Medical Radiography and Photography, Band 23Eastman Kodak Company, 1947 |
Im Buch
Ergebnisse 1-3 von 24
Seite 5
A B C D FIGURE 3 - A series of radiographs that demonstrate the effect of time of development on the visualization of the radio- graphic image . Radiographs A , B , and C received 5 Ma.S. exposure . The kilovoltage was 60 ; the distance ...
A B C D FIGURE 3 - A series of radiographs that demonstrate the effect of time of development on the visualization of the radio- graphic image . Radiographs A , B , and C received 5 Ma.S. exposure . The kilovoltage was 60 ; the distance ...
Seite 30
... radiographs : DISTANCE 60 cm . FILM Eastman Blue Brand Kv . MA.S. 60 60 COMMENT : This is the second case of sequestrum of the temporal bone associated with tubercu- losis observed in the author's practice . CONGENITAL ESOPHAGEAL ...
... radiographs : DISTANCE 60 cm . FILM Eastman Blue Brand Kv . MA.S. 60 60 COMMENT : This is the second case of sequestrum of the temporal bone associated with tubercu- losis observed in the author's practice . CONGENITAL ESOPHAGEAL ...
Seite 56
... RADIOGRAPHIC EXAMINATION : A lateral ra- diograph ( Figure 7 ) and other radiographs made following the ingestion of a barium sulfate sus- pension showed the thoracic esophagus to be very MEDIASTINAL TUMORS OF PROBABLE ECHINOCOCCAL ...
... RADIOGRAPHIC EXAMINATION : A lateral ra- diograph ( Figure 7 ) and other radiographs made following the ingestion of a barium sulfate sus- pension showed the thoracic esophagus to be very MEDIASTINAL TUMORS OF PROBABLE ECHINOCOCCAL ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
14x17-inch Blue Brand 5-minute development BLUE BRAND FILM Blue Brand X-ray bone Brand X-ray Film Bronchiectasis camera characteristic curves clinical colitis color common bile duct curves demonstrating effects DENSITY OF IMAGE derived curves demonstrating DEVEL Developer and Replenisher developer solution developing agent development at 68°F diagnosis Dye Transfer Eastman Blue Brand Eastman Kodak Company Eastman No-Screen X-ray Ektachrome employed emulsion esophageal atresia esophagus Film in solution film speed fixer fresh developer fresh solution gallons of solution graphic Hospital illustrations increases in developing INFRARED PHOTOGRAPHY intermittent agitation Internal acoustic meatus Kodachrome Kodak Dye Transfer Kodak Liquid X-ray Kodak radiographic developers Kodak Rapid X-ray Kodak X-ray Developer Liquid X-ray Developer LOGARITHM OF RELATIVE Medical Radiography ment minutes at 68°F NO-SCREEN FILM No-Screen X-ray Film operation patient photographic Published radio Radiologist Radiology Rapid X-ray Developer Rochester shown in Figure slides specimen speed and contrast surgical tank technic temporal bone tion ulcerative colitis veloper