... ment . With any particular emulsion , the degree of development depends on the time of develop- ment , the temperature of the developer , the de- gree of agitation of the film or developer solution , and the activity of the developer ...
... ment . With any particular emulsion , the degree of development depends on the time of develop- ment , the temperature of the developer , the de- gree of agitation of the film or developer solution , and the activity of the developer ...
Seite 6
... ment of Blue Brand Film in Kodak Rapid X - ray Developer , development time is less critical and the developer solution is less sensitive to changes associated with exhaustion . The reduced sensi- tivity to developer exhaustion obtained ...
... ment of Blue Brand Film in Kodak Rapid X - ray Developer , development time is less critical and the developer solution is less sensitive to changes associated with exhaustion . The reduced sensi- tivity to developer exhaustion obtained ...
Seite 43
... ment Time Indicator , available on request to the Medical Division , Eastman Kodak Company , Rochester 4 , N. Y. 4 The manner in which changes in temperature affect the rate of development in solutions pre- pared from Kodak X - ray ...
... ment Time Indicator , available on request to the Medical Division , Eastman Kodak Company , Rochester 4 , N. Y. 4 The manner in which changes in temperature affect the rate of development in solutions pre- pared from Kodak X - ray ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
14x17-inch Blue Brand 5-minute development BLUE BRAND FILM Blue Brand X-ray bone Brand X-ray Film Bronchiectasis camera characteristic curves clinical colitis color common bile duct curves demonstrating effects DENSITY OF IMAGE derived curves demonstrating DEVEL Developer and Replenisher developer solution developing agent development at 68°F diagnosis Dye Transfer Eastman Blue Brand Eastman Kodak Company Eastman No-Screen X-ray Ektachrome employed emulsion esophageal atresia esophagus Film in solution film speed fixer fresh developer fresh solution gallons of solution graphic Hospital illustrations increases in developing INFRARED PHOTOGRAPHY intermittent agitation Internal acoustic meatus Kodachrome Kodak Dye Transfer Kodak Liquid X-ray Kodak radiographic developers Kodak Rapid X-ray Kodak X-ray Developer Liquid X-ray Developer LOGARITHM OF RELATIVE Medical Radiography ment minutes at 68°F NO-SCREEN FILM No-Screen X-ray Film operation patient photographic Published radio Radiologist Radiology Rapid X-ray Developer Rochester shown in Figure slides specimen speed and contrast surgical tank technic temporal bone tion ulcerative colitis veloper