Medical Radiography and Photography, Band 23Eastman Kodak Company, 1947 |
Im Buch
Ergebnisse 1-3 von 16
Seite 3
... emulsion of inherently high contrast developed for a short time in a low contrast de- veloper may produce low radiographic contrast ; on the other hand , an emulsion of inherently low contrast developed to somewhat more than its normal ...
... emulsion of inherently high contrast developed for a short time in a low contrast de- veloper may produce low radiographic contrast ; on the other hand , an emulsion of inherently low contrast developed to somewhat more than its normal ...
Seite 4
... EMULSION SPEED , PERCENT 100 ŏ 90 80 70 60 50 40 30 20 FIGURE 2 - Graph demonstrating changes in speed , contrast , and fog increment of Eastman Blue Brand X - ray Film with increase in time of development at 68 ° F . , and with inter ...
... EMULSION SPEED , PERCENT 100 ŏ 90 80 70 60 50 40 30 20 FIGURE 2 - Graph demonstrating changes in speed , contrast , and fog increment of Eastman Blue Brand X - ray Film with increase in time of development at 68 ° F . , and with inter ...
Seite 39
... emulsion and the re- sulting radiographic density . These graphic representations are known as the characteristic curves of the emulsions . ( As was pointed out in Part One , the slope of this curve - gamma - is the measure of the ...
... emulsion and the re- sulting radiographic density . These graphic representations are known as the characteristic curves of the emulsions . ( As was pointed out in Part One , the slope of this curve - gamma - is the measure of the ...
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
14x17-inch Blue Brand 5-minute development BLUE BRAND FILM Blue Brand X-ray bone Brand X-ray Film Bronchiectasis camera characteristic curves clinical colitis color common bile duct curves demonstrating effects DENSITY OF IMAGE derived curves demonstrating DEVEL Developer and Replenisher developer solution developing agent development at 68°F diagnosis Dye Transfer Eastman Blue Brand Eastman Kodak Company Eastman No-Screen X-ray Ektachrome employed emulsion esophageal atresia esophagus Film in solution film speed fixer fresh developer fresh solution gallons of solution graphic Hospital illustrations increases in developing INFRARED PHOTOGRAPHY intermittent agitation Internal acoustic meatus Kodachrome Kodak Dye Transfer Kodak Liquid X-ray Kodak radiographic developers Kodak Rapid X-ray Kodak X-ray Developer Liquid X-ray Developer LOGARITHM OF RELATIVE Medical Radiography ment minutes at 68°F NO-SCREEN FILM No-Screen X-ray Film operation patient photographic Published radio Radiologist Radiology Rapid X-ray Developer Rochester shown in Figure slides specimen speed and contrast surgical tank technic temporal bone tion ulcerative colitis veloper