Medical Radiography and Photography, Bände 29-30Eastman Kodak Company, 1953 |
Im Buch
Ergebnisse 1-3 von 4
Seite 37
... cassette holder facing the x - ray tube . If brought to the x - ray department on a carrier , he is asked to sit up with his back to the cassette holder . If he is in a wheel chair , the cassette is placed be- tween his back and that of ...
... cassette holder facing the x - ray tube . If brought to the x - ray department on a carrier , he is asked to sit up with his back to the cassette holder . If he is in a wheel chair , the cassette is placed be- tween his back and that of ...
Seite 41
... cassette holder , with the bridge of the nose opposite the centering point . The cylinder is extended 2 inches . The central ray is projected at a caudal angle of 15 degrees through the glabella to the centering point . Posteroanterior ...
... cassette holder , with the bridge of the nose opposite the centering point . The cylinder is extended 2 inches . The central ray is projected at a caudal angle of 15 degrees through the glabella to the centering point . Posteroanterior ...
Seite 42
... cassette holder , with the medi- an plane parallel with the holder . The radio- graphic base line is aligned parallel with the hori- zontal line of the holder . The outer canthus should be aligned 1⁄2 inch above and 1⁄2 inch anterior to ...
... cassette holder , with the medi- an plane parallel with the holder . The radio- graphic base line is aligned parallel with the hori- zontal line of the holder . The outer canthus should be aligned 1⁄2 inch above and 1⁄2 inch anterior to ...
Inhalt
Abschnitt 1 | 21 |
Abschnitt 2 | 29 |
Abschnitt 3 | 53 |
Urheberrecht | |
2 weitere Abschnitte werden nicht angezeigt.
Andere Ausgaben - Alle anzeigen
Häufige Begriffe und Wortgruppen
abdominal acromioclavicular articulation anatomy aneurysm angiocardiography angle anteroposterior aorta appearance auricular surface barium birefringent blood vessels bone bronchial arteries camera cassette holder central ray cephalad chest clavicle clinical close-up colon color contrast degrees demonstrated Department of Radiology diagnosis disease Eastman Kodak Company employed epididymis equipment esophagus examination exposure field filters Flexichrome fluorescent fluoroscopic gallbladder gallstones graphic graphs heart Hospital iliac illustrations inches injection joint lateral latex lens lesions ligament light lung Medical Division Medical Photography Medical Radiography mirror normal oblique optical Outfit pathologic patient pelvis photographs plane portion position posterior posteroanterior present Price procedure progeria projection pulmonary artery pulmonary veins radiation radio radiographs radiologist Radiology records result Rochester Roentgen Roentgenol rotation sacroiliac articulation showed shown in Figure skull specimen spherical supine technic therapy tion tissue tube tumor upper vertical vinyl acetate visualized X-ray Film York